Rego 800 Installation

Interface install instructions for the IVT Optima- 290 A/W and Premiumline X15/X11 heat pump interface.

Steps to install 

  1. Power down the heat pump and open the front cover.
  2. Remove the cover of the electronic box.
  3. Locate any available can bus connector.
  4. Connect as pictured below. (Blue GND, Purple +12v)
  5. Assemble covers and heat pump front.
  6. Connect interface to H66
  7. Power up the heat pump.

                 