IDX | Name | Description |
0002 | Radiator forward |
Temperature water feed out to radiators |
0003 | Heat carrier return | Temperature HP internal heat carrier return. |
0004 | Heat carrier forward | Temperature HP internal heat supply forward |
0005 | Brine in/Evaporator | Temperature Supply in from ground source for L/W pumps, Evaporator for A/W & E/W pumps. |
0006 | Brine out/Condenser | Temperature Supply out to ground source for L/W pumps, Condenser for A/W & E/W pumps. |
0007 | Outdoor | Temperature of Outdoor sensor |
0008 | Indoor | Temperature of cable connected indoor sensor if installed |
0021 | Indoor 2 | Temperature of wireless indoor sensor if installed |
0009 | Warm water Top | Temperature of warm water tank, top sensor |
000A | Warm water Mid | Temperature of warm water tank, mid sensor |
000B | Hot Gas | Temperature of Hot gas from compressor before expansion valve |
000C | Suction Gas | Temperature if Suction gas after expansion valve |
000E | Air intake | Temperature if Air Intake för E/W pumps |
0020 | Radiator forward 2 | Temperature feed to radiators for heat circuit 2 if installed |
0011 | Pool | Temperature if Pool if installed |
3109 | Circ pump speed | Percentage of variable speed for circulation pump |
3110 | Brine pump speed | Percentage of variable speed for Brine pump (L/W pumps only) |
9108 | Compressor speed | Kilowatt usage of variable compressor operations |
3108 | Compressor speed | Percentage speed of variable compressor operations |
0107 | Heating setpoint | |
0111 | ||
3104 | ||
3128 | ||
1A01 | ||
1A04 | ||
1A05 | ||
1A06 | ||
1A07 | ||
1 | ||